Endobronchial tubes - a case for re-evaluation.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 16704596.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An endobronchial tube (Macintosh-Leatherdale) was used to secure the airway for a tracheal resection and end-to-end anastomosis. This lung separation device enabled insertion of both a fibreoptic bronchoscope and a tube exchange catheter. These were required after the trachea was transected and re-anastomosis proved surgically difficult. The airway exchange catheter allowed for jet ventilation and later a tube change when an emergency occurred. Options and management issues for tracheal surgery and lung separators are discussed. A case is made for a re-evaluation of endobronchial tubes both as a useful conduit for modern airway instruments and as an alternative to small double-lumen tubes for the increasing population of obese patients weighing > 100 kg, requiring thoracic surgery.
Medical subject headings
- Intubation, Intratracheal
- Tracheal Neoplasms