Comparison of two delivery methods of local anesthetic distribution after intra-articular knee injection.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 16729745.
- Also identified by DOI 10.3928/01477447-20060501-05.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We studied the intra-articular distribution of radiopaque dye to compare the efficacy of a continuous low-volume infusion with an intermittent high-volume bolus infusion. Knee arthroscopy patients were randomized with 10 cc of dye infused over 2.5 hours versus 10 cc bolus of dye. Radiographs were independently evaluated. Eleven knees (low-volume infusion) filled an average of 3 of 7 compartments, while 10 knees (bolus group) had complete filling of all seven compartments (P < .001). This study supports high-volume bolus injections of local anesthetics to achieve consistent distribution to all knee compartments while enhancing pain control.
Medical subject headings
- Anesthetics, Local
- Arthralgia
- Injections, Intra-Articular
- Knee Joint
Anatomy
- knee