Nonlinear finite element model predicts vertebral bone strength and fracture site.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 16845352.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A study on computed tomography (CT)-based finite element (FE) method that predicts vertebral strength and fracture site using human cadaveric specimens. To evaluate the accuracy of the nonlinear FE method by comparing the predicted data with those of mechanical testing. FE methods may predict vertebral strength and fracture site but the prediction has been difficult because of a complex geometry, elastoplasticity, and thin cortical shell of the vertebra. FE models of the 12 thoracolumbar vertebral specimens were constructed. Nonlinear FE analyses were performed, and the yield load, the fracture load, the sites where elements failed, and the distribution of minimum principal strain were evaluated. A quasi-static uniaxial compression test for the same specimens was conducted to verify these analyses. The yield loads, fracture loads, minimum principal strains, and fracture sites of the FE prediction significantly correlated with those measured. Nonlinear FE model predicted vertebral strength and fracture site accurately.
Medical subject headings
- Finite Element Analysis
- Lumbar Vertebrae
- Models, Biological
- Nonlinear Dynamics
- Spinal Fractures
- Thoracic Vertebrae
- Tomography, X-Ray Computed
Anatomy
- lumbar spine
- thoracic spine