Intraocular pressure change during hemodialysis.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 16876525.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate intraocular pressure (IOP) change through hemodialysis and examine other factors to affect IOP change in patients treated with hemodialysis. Prospective, observational case series. IOP, blood pressure, and plasma colloid osmotic pressure (COP) were measured in 188 eyes of 95 patients receiving hemodialysis in Nantan General Hospital. IOP significantly decreased after hemodialysis (P = 0.006). Body weight, systolic and diastolic blood pressure also decreased significantly (P < 0.001). COP significantly increased (P < 0.001). Change in IOP correlated negatively with COP change (OD; r = -0.196, OS; r = -0.339) and positively with change in body weight (OD; r = -0.278, OS; r = -0.357). IOP tended to increase after hemodialysis in patients receiving hemodialysis for more than 12 years. IOP decrease during hemodialysis may be due to COP increase. Patients receiving hemodialysis for a long time are more likely to show IOP increase after hemodialysis.
Medical subject headings
- Intraocular Pressure
- Renal Dialysis