Forearm cephalic vein cross-sectional area changes at incremental congestion pressures: towards a standardized and reproducible vein mapping protocol.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 16890868.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Duplex ultrasonography assessment of superficial forearm veins is frequently used before a hemodialysis arteriovenous fistula (AVF) is created. There is, however, no standardized preoperative duplex ultrasonography protocol. This study assessed B-mode image analysis reproducibility and reproducibility of repeated forearm superficial venous diameter measurements on different days at different venous congestion pressures (VCPs). Diameters were determined using B-mode ultrasonography in 10 healthy male volunteers on days 1 and 14 at incremental VCP values (10 to 80 mm Hg). Intra- and interobserver agreement was assessed for B-mode image analysis by calculating interclass correlation coefficients (ICC). Reproducibility of repeated diameter measurements (maximum and minimum diameter at days 1 and 14), cross-sectional area size increase, and shape change due to incremental VCPs were determined by calculating ICC values. Analysis of intraobserver agreement of B-mode image interpretation yielded ICC values of 0.97 (95% confidence interval [CI], 0.94 to 0.99) and 0.97 (95% CI, 0.96 to 0.99) for determination of maximum and minimum diameters, respectively. Interobserver agreement analysis yielded ICC values of 0.95 (95% CI, 0.92 to 0.97) and 0.96 (95% CI, 0.96 to 0.99) for determination of maximum and minimum diameters, respectively. Reproducibility of repeated diameter measurements on days 1 and 14 improved substantially at incremental VCP values, with best reproducibility at VCPs >40 mm Hg. Repeated determination of cross-sectional area size increase and shape change due to VCP increase from 10 to 80 mm Hg yielded ICC values of 0.49 (95% CI, 0.19 to 1.00) and 0.09 (95% CI, 0.00 to 0.92), respectively. Maximum and minimum diameters as well as cross-sectional area size increased significantly (P < .01) due to VCP increase during both sessions. Cross-sectional area shape changed significantly (P < .01) due to VCP increase during both sessions. Diameter measurements on B-mode images are largely observer independent. Superficial venous cross-sectional area shape is noncircular, and cross-sectional area size depends on VCP. Both maximum and minimum venous diameters should be determined at VCPs >40 mm Hg to attain the best reproducibility. Further studies are needed to determine whether a standardized preoperative vein mapping protocol can reduce AVF nonmaturation rates.
Medical subject headings
- Forearm
- Veins
- Venous Pressure