The value of urine specific gravity in detecting diabetes insipidus in a patient with uncontrolled diabetes mellitus: urine specific gravity in differential diagnosis.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 17026722.
- Also identified by PMC identifier 1831666.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
When a patient with diabetes mellitus presents with worsening polyuria and polydipsia, what is a sensible, cost-effective approach? We report the unique coincidence of type 2 diabetes mellitus and diabetes insipidus. A 46-year-old woman with poorly controlled type 2 diabetes complained of polyuria with a daily output of 5 L. Although urinalysis demonstrated significant glucosuria, diabetes insipidus was suspected owing to a low urine specific gravity (1.008). The low specific gravity persisted during a water deprivation test. Ultimately, diabetes insipidus was confirmed when urine specific gravity and urine osmolality normalized following desmopressin administration. This case emphasizes the importance of accurately interpreting the urine specific gravity in patients with polyuria and diabetes mellitus to detect diabetes insipidus.
Medical subject headings
- Diabetes Insipidus
- Diabetes Mellitus, Type 2