Less invasive total hip arthroplasty: description of a new technique.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 17027549.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We describe a new technique and aim to justify its use in total hip arthroplasty. The incision is short and there is minimal soft tissue dissection: piriformis and most of quadratus femoris remain intact. A meticulous capsular repair is performed. Patients are mobilized without restrictions. One hundred total hip arthroplasties by the standard posterior approach (group 1) were compared with 100 by the less invasive approach (group 2). Minimum follow-up was 2 years. Mean blood loss in group 1 was higher (P < .0001) and inpatient stay longer (P < .0001). There was greater improvement in WOMAC scores for up to 1 year in the less invasive group (P = .027). In conclusion, the less invasive approach is safe and the functional benefits last up to 1 year.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Minimally Invasive Surgical Procedures
Anatomy
- hip