MDCT of right ventricular function: comparison of right ventricular ejection fraction estimation and equilibrium radionuclide ventriculography, part 1.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 17114556.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to calculate right ventricular ejection fraction by use of ECG-gated MDCT and to compare the results with those of equilibrium radionuclide ventriculography. Forty-nine consecutively examined patients (30 men, 19 women; mean age, 59 years) with known or suspected right ventricular dysfunction secondary to bronchopulmonary (n = 30) or pulmonary vascular (n = 19) disease underwent ECG-gated 16-MDCT angiography of the heart (rotation time, 0.42 second; 120 kV; 300 mAs; collimation, 12 x 0.75 mm; pitch, 0.2) after CT angiographic examination of the entire thorax according to a standard protocol. Biphasic administration of a 30% contrast agent was systematically performed (phase 1, 90 mL at 3 mL/s; phase 2, 30 mL at 1.5 mL/s); no patient received additional medication. Right ventricular ejection fraction was calculated after two reviewers in consensus determined the reconstruction windows and segmentation of the right ventricular cavity on a series of diastolic and systolic short-axis images. The results were compared with those of equilibrium radionuclide ventriculography. At data acquisition, the mean (+/- SD) heart rate of the study group was 82 +/- 13.87 beats per minute (BPM) (range, 51-115 BPM). ECG showed a sinus rhythm in 30 (61%) of the patients and irregular cardiac rhythm in 19 (39%) of the patients. Agreement between the two techniques was estimated by intraclass correlation coefficient (0.77), the method of Bland and Altman (limits of concordance, -14.9 and 13.7), and percentage of variability between two measurements expressed by mean absolute percentage error (12.1%). The estimated effective dose for heart examination was 7.48 mSv with CT and 5 mSv with scintigraphy. The mean effective dose for the chest and heart CT examinations was 11.64 mSv. Right ventricular ejection fraction can be reliably estimated with 16-MDCT in unselected patients.
Medical subject headings
- Radionuclide Ventriculography
- Stroke Volume
- Tomography, X-Ray Computed
- Ventricular Dysfunction, Right
- Ventricular Function, Right