Impaction grafting for femoral component revision using a non-polished bead-blasted chrome cobalt stem-average 8 1/2-year follow-up.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 17162179.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Impaction grafting for femoral component revision in patients with significant bone loss has been reported using a tapered polished femoral component that is meant to subside. This study reports our results of femoral component revision using impaction grafting with a bead-blasted chrome cobalt stem designed not to subside. Forty-eight femoral component revisions using impaction grafting were retrospectively reviewed with a minimum 6 1/2-year follow-up. There were 2 failures due to aseptic loosening of the femoral component (4%). There were 22 total complications, and the overall failure rate was 21%. Impaction grafting for femoral component revision using a bead-blasted chrome cobalt stem in patients with a large femoral canal diameter has shown good results with respect to aseptic loosening with minimal subsidence.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
Anatomy
- femur
- hip