Clinical values in computer-assisted total knee arthroplasty.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 17190171.
- Also identified by DOI 10.3928/01477447-20061201-04.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Thirty posterior stabilized total knee prostheses implanted using a computed tomography-free navigation system were compared to a control group of 30 matched total knee prostheses of the same type implanted via a classical, surgeon-controlled technique. The accuracy of the implantations in relation to the mechanical axis in the navigation group was superior to that of the manual group. Early two-year clinical results including range of motion and Knee Society Clinical Rating Score were equally good compared to the manual group. However, potential long-term outcome and functional improvement require further investigation.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Joint Diseases
- Monitoring, Intraoperative
- Surgery, Computer-Assisted
- Tomography, X-Ray Computed
Anatomy
- knee