Heart rate changes are insensitive for detecting postasphyxial seizures in neonates.

Cherian, P J; Blok, J H; Swarte, R M; Govaert, P; Visser, G H · Neurology · 2006

case_series · Level IV

Where this comes from

Abstract

We studied heart rate (HR) changes during 169 seizures (mean 12 per patient, range 8 to 18) in 14 neonates with severe birth asphyxia. HR changes were found in 21 seizures (12.4%) in eight patients (HR increases in four, decreases in one, and both patterns in three patients), suggesting the existence of neonatal cerebral hemispheric connections with brainstem autonomic regulatory centers. HR monitoring appears to be insensitive for detecting postasphyxial neonatal seizures.