Gait analysis of patients with resurfacing hip arthroplasty compared with hip osteoarthritis and standard total hip arthroplasty.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 17197316.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Patients with standard total hip arthroplasties may have reduced hip abduction and extension moments when compared with normal nonosteoarthritic hips. In comparison, patients after resurfacing total hip arthroplasty appear to have a near-normal gait. The authors evaluated temporal-spatial parameters, hip kinematics, and kinetics in hip resurfacing patients compared with patients with unilateral osteoarthritic hips and unilateral standard total hip arthroplasties. Patients with resurfacing walked faster (average 1.26 m/s) and were comparable with normals. There were no significant differences in hip abductor and extensor moments of patients with resurfacing compared with patients in the standard hip arthroplasty group. This study showed more normal hip kinematics and functionality in resurfacing hip arthroplasty, which may be due to the large femoral head.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Gait
- Osteoarthritis, Hip
Anatomy
- hip
- femur