Intra-operative error during Austin Moore hemiarthroplasty.

Weinrauch, P · J Orthop Surg (Hong Kong) · 2006

retrospective_cohort · Level III

Where this comes from

Abstract

To examine the frequency of technical errors during implantation of the Austin Moore prosthesis in a public hospital. Radiographs and charts of 147 consecutive uncemented Austin Moore hemiarthoplasty patients were retrospectively reviewed with particular reference to intra-operative errors associated with early failure of the prosthesis. 48% of the patients had at least one error pertinent to implantation and 14% sustained intra-operative fractures. The error rates between relatively junior doctors and consultants were not significantly different. The uncemented Austin Moore prosthesis is a technically demanding prosthesis that is difficult to implant well. Greater selectivity should be exercised when considering its use for femoral neck fractures.

Medical subject headings

Anatomy