Irreversible myocardial injury: assessment with cardiovascular delayed-enhancement MR imaging and comparison of 1.5 and 3.0 T--initial experience.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 17209167.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To prospectively compare visualization and quantification of irreversible myocardial injury in patients with chronic myocardial infarction at 1.5- and 3.0-T magnetic resonance (MR) imaging. The institutional research ethics committee approved the study. Participants gave written informed consent. Sixteen male patients (mean age, 66 years +/- 13 [standard deviation]) with myocardial infarction were imaged with the same sequence by the same operator at 1.5 and 3.0 T. After cine imaging, a bolus of gadodiamide was administered. Short-axis images of entire left ventricle (LV) were acquired with a breath-hold T1-weighted segmented inversion-recovery turbo fast low-angle shot (FLASH) sequence. Agreement for myocardial hyperenhancement (HE) mass between field strengths was assessed with Bland-Altman method; agreement for detection and transmural extent of HE was assessed with kappa statistics. Intra- and interobserver reproducibility of mass and transmural extent of HE were assessed at 1.5 and 3.0 T. Bland-Altman analysis revealed no systematic bias (mean difference, 0.2 g; 95% confidence interval: -0.7 g, 1.2 g) and acceptable limits of agreement (-3.3 to 3.8 g) between field strengths for HE mass. HE mass measurements were strongly correlated (R(2) = 0.99); there was no significant difference in measurements at 1.5 and 3.0 T (28.1 g +/- 15.7 [22.6% +/- 10.9 of LV mass] vs 27.8 g +/- 15.7 [22.3% +/- 10.7 of LV mass], respectively; P = .599). For all segments, there was a high degree of agreement for HE detection (kappa = 0.90) and transmural grade (kappa = 0.79) between field strengths. Intra- and interobserver variability were low between both field strengths. Initial inversion time selected to null the signal of normal myocardium at 3.0 T was 57 msec +/- 20 longer than at 1.5 T (P < .01). By using the same turbo FLASH MR pulse sequence, there was strong agreement in mass and transmural extent of myocardial HE between 1.5 and 3.0 T.
Medical subject headings
- Gadolinium DTPA
- Image Enhancement
- Image Interpretation, Computer-Assisted
- Magnetic Resonance Imaging
- Myocardial Infarction
- Ventricular Dysfunction, Left