Triggering at the distal A2 pulley.

Nagaoka, M; Yamaguchi, T; Nagao, S · J Hand Surg Eur Vol · 2007

case_report · Level V

Where this comes from

Abstract

We report two cases with triggering at the distal end of the A2 pulley. One was caused by enlargement of the flexor digitorum profundus (FDP) tendon and the other by enlargement of both slips of the flexor digitorum superficialis (FDS) tendon. Both were relieved by reduction tenoplasty and short releases, or venting, of the distal A2 pulley.