Multisite recording of extracellular potentials produced by microchannel-confined neurons in-vitro.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 17278590.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Towards establishing electrical interfaces with patterned in vitro neurons, we have previously described the fabrication of hybrid elastomer-glass devices polymer-on-multielectrode array technology and obtained single-electrode recordings of extracellular potentials from confined neurons (Claverol-Tinturé et al., 2005). Here, we demonstrate the feasibility of spatially localized multisite recordings from individual microchannel-guided neurites extending from microwell-confined somas with good signal-to-noise ratios (20 dB) and spike magnitudes of up to 300 microV. Single-cell current source density (scCSD) analysis of the spatio-temporal patterns of membrane currents along individual processes is illustrated.
Medical subject headings
- Action Potentials
- Cell Culture Techniques
- Microelectrodes
- Nerve Net
- Neurons
- Snails