A comparison of laser-assisted drug delivery at two output energies for enhancing the delivery of topically applied LMX-4 cream prior to venipuncture.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 17377092.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Laser-assisted drug delivery (LAD) has the potential for facilitating topical anesthesia with reduced onset time. In this randomized, double-blind, crossover study we compared the efficacy and adverse event profile of LAD for topical anesthesia before venipuncture using two output energies (2.0 and 3.5 J/cm2). Mean Visual Analog Scale pain scores were not statistically different (P = 0.57) between the low-energy (mean = 6.7) and high-energy (mean = 8.1) lasers. LAD at an energy of 2.0 J/cm2 (570 mJ) is as effective, with similar adverse events, as an energy of 3.5 J/cm2 (1000 mJ) in facilitating topical anesthesia.
Medical subject headings
- Anesthetics, Local
- Drug Delivery Systems
- Lasers
- Lidocaine
- Pain
- Phlebotomy