68Ga-DOTA-Tyr3-octreotide PET in neuroendocrine tumors: comparison with somatostatin receptor scintigraphy and CT.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 17401086.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to evaluate the diagnostic value of a new somatostatin analog, (68)Ga-labeled 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid-d-Phe(1)-Tyr(3)-octreotide ((68)Ga-DOTA-TOC), for PET in patients with known or suspected neuroendocrine tumors. PET was compared with conventional scintigraphy and dedicated CT. Eighty-four patients (48 men, 36 women; age range, 28-79 y; mean age +/- SD, 58.2 +/- 12.2 y) were prospectively studied. For analysis, patients were divided into 3 groups: detection of unknown primary tumor in the presence of clinical or biochemical suspicion of neuroendocrine malignancy (n = 13 patients), initial tumor staging (n = 36 patients), and follow-up after therapy (n = 35 patients). Each patient received 100-150 MBq (68)Ga-DOTA-TOC. Imaging results of PET were compared with (99m)Tc-labeled hydrazinonicotinyl-Tyr(3)-octreotide ((99m)Tc-HYNIC-TOC) and (111)In-DOTA-TOC. CT was also performed on every patient using a multidetector scanner. Each imaging modality was interpreted separately by observers who were unaware of imaging findings before comparison with PET. The gold standard for defining true-positive (TP), true-negative (TN), false-positive (FP), and false-negative (FN) results was based on all available histologic, imaging, and follow-up findings. PET was TP in 69 patients, TN in 12 patients, FP in 1 patient, and FN in 2 patients, indicating a sensitivity of 97%, a specificity of 92%, and an accuracy of 96%. The FP finding was caused by enhanced tracer accumulation in the pancreatic head, and the FN results were obtained in patients with a tumor of the gastrointestinal tract displaying liver metastases. (68)Ga-DOTA-TOC showed higher diagnostic efficacy compared with SPECT (TP in 37 patients, TN in 12 patients, FP in 1 patient, and FN in 34 patients) and diagnostic CT (TP in 41 patients, TN in 12 patients, FP in 5 patients, and FN in 26 patients). This difference was of statistical significance (P < 0.001). However, the combined use of PET and CT showed the highest overall accuracy. (68)Ga-DOTA-TOC PET shows a significantly higher detection rate compared with conventional somatostatin receptor scintigraphy and diagnostic CT with clinical impact in a considerable number of patients.
Medical subject headings
- Gallium Radioisotopes
- Octreotide
- Radionuclide Imaging
- Receptors, Somatostatin
- Tomography, X-Ray Computed
- Tyrosine