Ultrasound screening in developmental hip dysplasia: do all scanned hips need to be followed up?
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 17414780.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Many ways of detecting hip instability in the newborn infant exist, including a history of risk factors, clinical examination and ultrasound. We investigated our practice of 'at risk' screening using subjective, dynamic and static, ultrasound, followed by radiographic evaluation at 12 months. We found that the average age at presentation was 71 days, with the most common reason for referral being a clicking hip. None of the hips deemed stable under review deteriorated, and all those considered normal at first visit had a normal radiograph at 12 months. Abnormal radiographs were found in all the other groups.
Medical subject headings
- Hip Dislocation, Congenital
- Neonatal Screening
Anatomy
- hip