Use of covered stents and endograft as a rescue treatment in a patient with a complex form of recurrent aortic coarctation.

Parodi, Juan C; Ferreira, Luis Mariano; Faella, Horacio; La Mura, Ricardo; Ruslender, Erik; Henestrosa, German · J Vasc Surg · 2007

case_report · Level V

Where this comes from

Abstract

We report our experience with one patient with recurrent coarctation and aneurysm degeneration treated endoluminally. A novel technique was used combining balloon-expandable with self-expandable endografts. The balloon-expandable component expanded the area of stenosis and also created a neck to allow the implantation of the self-expandable endograft to exclude the aneurysm. Mismatch of diameters was solved with the creation of a new proximal neck, in which the distal end was progressively expanded to reach the appropriate diameter to implant the self-expandable endograft inside. Expansion of the narrow stenosis and complete exclusion of the aneurysm was achieved without a residual pressure gradient.