Rotating-hinge total knee arthroplasty in a patient with genu recurvatum after osteomyelitis of the distal femur.

Nishitani, Kohei; Nakagawa, Yasuaki; Suzuki, Takashi; Koike, Kazuhiro; Nakamura, Takashi · J Arthroplasty · 2007

case_report · Level V

Where this comes from

Abstract

An 80-year-old man presented to our clinic with a chief complaint about pain and stiffness in the right knee. His history was significant for osteomyelitis of the right femur 64 years ago. Examination revealed a range of motion from 30 degrees hyperextension to 0 degrees extension. A rotating-hinge total knee arthroplasty was performed. Four years later, the patient ambulates painlessly with 1 cane. He has no extensor lag, and his range of motion is 0 degrees to 15 degrees.