Comparison of MR arthrography with arthroscopy of the hip for the assessment of intra-articular loose bodies.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 17618435.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess the specificity and sensitivity of MR arthrography of the hip in comparison with arthroscopy for the evaluation of intra-articular loose bodies. Over a 3-year period, 81 consecutive patients underwent a total of 82 hip arthroscopies by a single orthopedic surgeon for intractable hip pain. Of the 82 arthroscopies, 70 had pre-operative MR arthrograms. Of these, 57 were available for retrospective review, after which they were compared with the operative notes of the subsequent arthroscopies. Of 82 arthroscopies 16 (20%) demonstrated intra-articular loose bodies, while, in the study group, nine of 57 had loose bodies (16%). There was a total of seven discordant cases (five false negatives and two false positives). The sensitivity of MR arthrography for detection of intra-articular loose bodies was 44%, while the specificity was 96%. While the specificity of MR arthrography for the detection of intra-articular loose bodies was high (96%), the sensitivity was not nearly as good (44%).
Medical subject headings
- Arthrography
- Arthroscopy
- Hip Joint
- Joint Loose Bodies
- Magnetic Resonance Imaging
Anatomy
- hip