Optimal skin surface landmark for the SVC-RA junction in cancer patients requiring the implantation of permanent central venous catheters.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 17635431.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We compared four different skin surface landmarks, the lower margin of the right 2nd costo-sternal junction (point A); the upper margin of the right 3rd costo-sternal junction (point B); the lower margin of the right 3rd costo-sternal junction (point C); and a point 5 cm below the manubrio-sternal junction (point D), in 20 cancer patients undergoing insertion of permanent central venous catheters whose tips were placed near the superior vena cava - right atrium (SVC-RA) junction under transoesophageal echocardiography guidance. The landmark was satisfactory if it was located within 1 cm of the SVC-RA junction. Points C and D were closer to the SVC-RA junction than points A and B (p < 0.0001). However, point C had the highest incidence (C: 70%, A: 0%, B: 20%, D: 30%, p < 0.0001) of being within 1 cm of the SVC-RA junction.
Medical subject headings
- Catheterization, Central Venous
- Neoplasms
- Skin