Ceramic-on-ceramic total hip arthroplasty early dislocation rate.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 17667324.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Wear debris from metal-on-polyethylene articulation in conventional total hip arthroplasty can limit the implant's longevity. Modern ceramic material with high wear resistance and low fracture risk has the potential to extend the lifetime of total hip arthroplasty, which makes the procedure potentially more suitable for young, active patients. Concerns with brittle ceramic material include fracture risk, the "squeak" phenomenon, and potentially a higher dislocation rate secondary to limited neck lengths and liner options. We therefore determined the early dislocation rate in modern ceramic-on-ceramic total hip arthroplasty. In 1635 total hip arthroplasties performed over the 9-year period (1996-2005), we observed three anterior and 15 posterior dislocations (1.1%). All were treated successfully, one with a revision and 17 with closed reduction under general anesthesia. Ceramic-on-ceramic total hip arthroplasty can be a good alternative bearing surface with a low dislocation rate.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Ceramics
- Hip Joint
- Hip Prosthesis
- Joint Dislocations
Anatomy
- hip