Factors affecting the impingement angle of fixed- and mobile-bearing total knee replacements: a laboratory study.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 17689786.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Maximum flexion-or impingement angle-is defined as the angle of flexion when the posterior femoral cortex impacts the posterior edge of the tibial insert. We examined the effects of femoral component placement on the femur, the slope angle of the tibial component, the location of the femoral-tibial contact point, and the amount of internal or external rotation. Posterior and proximal femoral placement, a more posterior femoral-tibial contact point, and a more tibial slope all increased maximum flexion, whereas rotation reduced it. A mobile-bearing knee gave results similar to those of the fixed-bearing knee, but there was no loss of flexion in internal or external rotation if the mobile bearing moved with the femur. In the absence of negative factors, a flexion angle of 150 degrees can be reached before impingement.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Knee Prosthesis
- Range of Motion, Articular
Anatomy
- femur
- knee
- tibia