Rotation affects apparent radiographic positioning of femoral components in total hip arthroplasty.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 1774573.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors have noted a change in the varus/valgus positioning of femoral components on anteroposterior (AP) radiographs that is dependent on limb rotation after total hip arthroplasty (THA). This effect, called pseudoposition, was demonstrated in six cadaver femurs implanted with an uncemented prosthesis that is noncanal-filling in the AP dimension. The distal tip of the prosthesis was positioned posteriorly in all specimens due to the bow of the femur. External rotation causes pseudovalgus positioning, and internal rotation causes pseudovarus positioning. Awareness of this phenomenon is important in the longitudinal analysis of femoral components after THA and emphasizes the need for standardized radiographic technique.
Medical subject headings
- Femur
- Hip Prosthesis
- Rotation
Anatomy
- femur
- hip