Matching intensity-modulated radiation therapy to an anterior low neck field.

Amdur, Robert J; Liu, Chihray; Li, Jonathan; Mendenhall, William; Hinerman, Russell · Int J Radiat Oncol Biol Phys · 2007

review · Level V

Where this comes from

Abstract

When using intensity-modulated radiation therapy (IMRT) to treat head and neck cancer with the primary site above the level of the larynx, there are two basic options for the low neck lymphatics: to treat the entire neck with IMRT, or to match the IMRT plan to a conventional anterior "low neck" field. In view of the potential advantages of using a conventional low neck field, it is important to look for ways to minimize or manage the problems of matching IMRT to a conventional radiotherapy field. Treating the low neck with a single anterior field and the standard larynx block decreases the dose to the larynx and often results in a superior IMRT plan at the primary site. The purpose of this article is to review the most applicable studies and to discuss our experience with implementing a technique that involves moving the position of the superior border of the low neck field several times during a single treatment fraction.

Medical subject headings