Micro pumping with cardiomyocyte-polymer hybrid.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 17896023.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This paper presents a hybrid micropump actuated by the up-down motion of a dome shaped cell-polymer membrane composite. The contractile force induced from self-beating cardiomyocytes cultured on the membrane causes shrinkage and relaxation of a microchamber, leading to a flow in a microchannel. Flow direction is controlled by the geometry of diffuser/nozzle in the microchannel. The fabrication process is noninvasive to cells, thus, cardiomyocytes can robustly maintain their activity for a long time. The fluid motion in the microchannel was monitored by tracking 2 microm polystyrene beads. A net flow rate of 0.226 nl min(-1) was obtained in our microscale device. Our device demonstrates a unique performance of a cell-microdevice hybrid lab-on-a-chip that does not require any external power source, preventing electrical or heat shock to analytes.
Medical subject headings
- Biomimetics
- Cell Culture Techniques
- Dimethylpolysiloxanes
- Microfluidic Analytical Techniques
- Myocardial Contraction
- Myocytes, Cardiac
- Polymers
- Silicones