Flexor tendon repair using the two-strand side-locking loop technique to tolerate aggressive active mobilization immediately after surgery.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 17920173.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Early mobilization after tendon repair decreases adhesion formation and improves repair-site strength. We investigated whether the two-strand side-locking loop technique would tolerate aggressive active mobilization immediately after surgery. Twelve flexor digitorum profundus tendons of the porcine forelimbs were sutured by the two-strand side-locking loop technique with a cross-stitch epitendinous repair (Group A), and by the 8-strand repair method with a simple running suture (Group B). Gaps and residual tensile strength after cyclic loadings of 3-50 N (for 10,000 rounds) were measured. Gaps after cyclic loading in Group A were 0.5+/-0.3 and 1.2+/-0.8 mm while those in Group B were 3.5+/-0.8 and 5.2+/-1.2 mm at 3 and 50 N, respectively. In addition, the respective residual tensile strength of Groups A and B were 207.1+/-15.2 and 84.2+/-18.3N. A combination of the two-strand side-locking loop technique with cross-stitch epitendinous repair served as the optimum suture method in establishing safe and early active mobilization without the aid of a specialized rehabilitation staff.
Medical subject headings
- Hand Injuries
- Suture Techniques
- Tendon Injuries
Anatomy
- hand