How precise is the determination of rotational alignment of the femoral prosthesis in total knee arthroplasty: an in vivo study.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 17920479.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Correct rotation of the femoral component is critical in avoiding patellar instability in total knee arthroplasty. This study attempted to compare the precision of 4 commonly used methods (transepicondylar axis [TEA], 3 degrees external rotation [ER] from posterior condylar line [PCL], perpendicular cut to Leo Whiteside line [WSL], and balanced flexion gap [GAP]) in determining the rotational alignment of the femoral prosthesis in an in vivo setting. The ranges of error were as follows: (1) TEA, 28 degrees (17 degrees internal rotation [IR] to 11 degrees ER); (2) PCL, 27 degrees (13 degrees IR to 14 degrees ER); (3) WSL, 32 degrees (17 degrees IR to 15 degrees ER); (4) GAP, 26 degrees (14 degrees IR to 12 degrees ER). If an error of more than 5 degrees from neutral alignment is defined as an outlier, 56% in TEA, 72% in PCL, 60% in WSL, and 20% in GAP methods would fall in the outlier zone.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Femur
- Image Processing, Computer-Assisted
- Knee Joint
- Surgery, Computer-Assisted
Anatomy
- femur
- knee