Fibular rotational osteotomy for the treatment of distal tibial osteochondroma: a technical modification for deformity correction and improved outcomes.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 17980846.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The technique of choice for excision of osteochondromas located in the lateral aspect of the tibia is a transfibular approach to expose the lesion for resection. A drawback of this approach is that removal of the lesion leaves a void that may cause a visible deformity and adversely affect long-term function. Fibular rotational osteotomy followed by fibular graft may minimize the resultant deformity, producing a more satisfactory functional and cosmetic result. The authors report a retrospective case series consisting of 5 cases in which a fibular graft rotation was performed after rotational osteotomy via a transfibular approach. Retrograde intramedullary fixation by means of a Kirschner wire, in combination with the design of the fibular osteotomy, provided rotational graft and fibular stability until healing occurred.
Medical subject headings
- Bone Neoplasms
- Fibula
- Osteochondroma
- Osteotomy
- Tibia
Anatomy
- tibia