Vaginal surgery for pelvic organ prolapse using mesh and a vaginal support device.

Carey, M; Slack, M; Higgs, P; Wynn-Williams, M; Cornish, A · BJOG · 2008

prospective_cohort · Level II

Where this comes from

Abstract

To describe a new surgical procedure for pelvic organ prolapse using mesh and a vaginal support device (VSD) and to report the results of surgery. A prospective observational study. Two tertiary referral Urogynaecology practices. Ninety-five women with International Continence Society pelvic organ prolapse quantification stage 2 or more pelvic organ prolapse who underwent vaginal surgery using mesh augmentation and a VSD. Surgery involved a vaginal approach with mesh reinforcement and placement of a VSD for 4 weeks. At 6 and 12 months, women were examined for prolapse recurrence, and visual analogue scales for satisfaction were completed. Women completed quality-of-life (QOL) questionnaires preoperatively and at 6 and 12 months. Objective success of surgery at 6 and 12 months following surgery. Secondary outcomes were subjective success, complications, QOL outcomes and patients' satisfaction. Objective success rate was 92 and 85% at 6 and 12 months, respectively. Subjective success rate was 91 and 87% at 6 and 12 months, respectively. New prolapse in nonrepaired compartments accounted for 7 of 12 (58%) failures at 12 months. Two of 4 mesh exposures required surgery. Sexual dysfunction was reported by 58% of sexually active women preoperatively and 23% at 12 months. QOL scores significantly improved at 12 months compared with baseline (P < 0.0001). Vaginal surgery using mesh and a VSD is an effective procedure for pelvic organ prolapse. However, further studies are required to establish the role of the surgery described in this study.

Medical subject headings