3-T MRI in the preoperative evaluation of depth of myometrial infiltration in endometrial cancer.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 18212237.
- Also identified by DOI 10.2214/AJR.07.2380.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective of our study was to evaluate the diagnostic accuracy of 3-T MRI in determining the depth of myometrial infiltration in patients with endometrial cancer. Fifty-two patients (43 postmenopausal) with histopathologically proven endometrial carcinoma underwent preoperative 3-T MRI. The following sequences were performed: axial T1 fast spin-echo (FSE); axial, parasagittal, and paracoronal T2 FSE; paracoronal 3D T1 inversion recovery gradient-echo after contrast administration; and parasagittal fat-suppressed T1 FSE. All patients underwent a hysterectomy. The MRI findings were compared with histopathology results. The quantity and degree of artifacts were evaluated. . MRI performed on a 3-T unit was in agreement with histopathology in assessing the depth of invasion in 86.4% (44/52) of the patients with a mean sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 83.5%, 93.9%, 77.8%, 92.2%, and 89.7%, respectively. Performance values were also assessed for single stages of myometrial infiltration. For the detection of an intramucosal lesion (MRI, 12/52; histopathology, 6/52), sensitivity was 100%; specificity, 86.9%; PPV, 50%; NPV, 100%; and accuracy, 88.5%. For the detection of myometrial infiltration that was less than 50% (MRI, 12/52; histopathology, 16/52), sensitivity was 62.5%; specificity, 94.4%; PPV, 83.3%; NPV, 85%; and accuracy, 84.6%. For the detection of myometrial infiltration that was greater than 50% (MRI, 28/52; histopathology, 30/52), sensitivity was 93.3%; specificity, 100%; PPV, 100%; NPV, 91.7%; and accuracy, 96.2%. The following artifacts were found: abdominal wall movement, nine patients (not affecting image quality); peristalsis, 16 patients (two deeply affecting, one affecting, and 13 scarcely affecting); magnetic susceptibility artifact, four patients (not affecting); chemical shift, 20 patients (four scarcely affecting and 16 not affecting); and dielectric effect, six patients (four deeply affecting and two affecting). In evaluating the depth of myometrial infiltration in patients with endometrial cancer, 3-T MRI showed high diagnostic accuracy-equivalent to that of 1.5-T MRI reported in the literature. Artifacts did not significantly affect image quality.
Medical subject headings
- Endometrial Neoplasms
- Endometrium
- Magnetic Resonance Imaging
- Preoperative Care