Internal endoconduit: an innovative technique to address unfavorable iliac artery anatomy encountered during thoracic endovascular aortic repair.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 18241768.
- Also identified by DOI 10.1016/j.jvs.2007.07.061.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Various strategies have been used to combat arterial access limitations encountered during thoracic endovascular aortic repair (TEVAR). Most require retroperitoneal dissection or aggressive angioplasty techniques that can lead to devastating complications. We describe a novel technique using an "internal endoconduit." Deployment of an iliac stent graft across the prohibitively stenotic area, followed by angioplasty and controlled rupture of the iliac artery, allows for safe passage of the delivery sheath. Adverse events associated with decreased pelvic perfusion or hemorrhage from iliac artery rupture are theoretically possible but have not been observed. Faced with unfavorable iliac anatomy, we use internal endoconduits rather than retroperitoneal access procedures and believe their use will increase the number of procedures that will be able to be performed through femoral access and substantially reduce the frequency of access-related complications.
Medical subject headings
- Angioplasty, Balloon
- Aortic Aneurysm, Thoracic
- Aortic Rupture
- Arterial Occlusive Diseases
- Blood Vessel Prosthesis Implantation
- Iliac Artery