Evaluation of intratester and intertester reliability of the Constant-Murley shoulder assessment.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18329560.
- Also identified by DOI 10.1016/j.jse.2007.06.024.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study evaluated the reliability of the Constant-Murley Score. Two testers assessed 63 patients twice on the same day using the original publication by Constant and Murley. The intratester reliability of the total score was high and the differences between the tests were small; 2 of 14 items were unreliable. The intertester reliability was high, but there were significant median differences of the total score; 12 of 14 items were unreliable. We believe that the differences between the testers were due to the brief explanations of test components in the original publication. The reliability of the Constant-Murley Score could possibly be improved by a better standardization of the assessment procedure.
Medical subject headings
- Health Status Indicators
- Observer Variation
- Shoulder
- Shoulder Joint
Anatomy
- shoulder