Microtubule curvatures under perpendicular electric forces reveal a low persistence length.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 18359849.
- Also identified by DOI 10.1073/pnas.0704169105 and PMC identifier 2786941.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The mechanics of microtubules, cylindrical protein filaments that constitute the cytoskeleton, have been well characterized on long length scales. Here, we investigate the persistence length of short (approximately 0.1 microm) ends of microtubules by measuring the trajectories of kinesin-propelled microtubules under perpendicular electric forces. We relate the measured trajectory curvatures to the biased thermal fluctuations of the leading microtubule end, and upon including all electrohydrodynamic forces, we find that the persistence length of the microtubule ends is only 0.08 +/- 0.02 mm. This is significantly shorter than the well established value of approximately 4-8 mm that is measured for long microtubules. Our data are in good agreement with recent theoretical predictions that microtubules mechanically behave as a loose assembly of independent protofilaments on these short length scales.
Medical subject headings
- Microtubules