Protecting a patellar ligament reconstruction after proximal tibial resection: a simplified approach.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18425561.
- Also identified by DOI 10.1007/s11999-008-0239-y and PMC identifier 2505243.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Limb salvage in tumor surgery has encouraged the development of megaprostheses. However, reattaching the ligamentum patellae poses a particular problem: avulsion and/or extensor lag may lead to poor function. We describe a new technique of patellar ligament reconstruction. The technique involves reattachment of the patellar ligament to the tibial tuberosity of the proximal tibial megaprosthesis, which has a porous surface created, and the repair is protected with a cerclage wire through the patella and the prosthesis. In 10 consecutive patients, the range of motion averaged 95 degrees (median, 90 degrees ; range, 70 degrees -120 degrees ), and the mean extension lag averaged 4 degrees (median, 0 degrees ; range, 0 degrees -20 degrees ). We had one case of patellar ligament avulsion. This technique resulted in good quadriceps function and a low incidence of complications. Level IV, therapeutic study.
Medical subject headings
- Bone Neoplasms
- Orthopedic Procedures
- Patellar Ligament
- Tibia
Anatomy
- knee
- tibia