Not the usual cardiac rhythm device infection: a fastidious pathogen with several teaching points.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 18438798.
- Also identified by DOI 10.1002/jhm.260.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Because cardiac device infections may include fastidious pathogens, extended incubation of blood cultures is suggested. A patient with an infection of a right ventricular lead implantable cardioverter defibrillator (ICD) system is described. The device was implanted 6 months earlier. The pathogen was identified as Haemophilus parainfluenzae, which was cultured within 72 hours and was presumably from a respiratory tract infection. Extended incubation was not necessary to culture this fastidious pathogen. Two large retrospective studies suggest that prolonged incubation for fastidious organisms is generally not necessary because of advances in culture media and automated blood culture systems.
Medical subject headings
- Defibrillators, Implantable
- Haemophilus Infections
- Prosthesis-Related Infections