Effect of the Total Facet Arthroplasty System after complete laminectomy-facetectomy on the biomechanics of implanted and adjacent segments.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 18440280.
- Also identified by DOI 10.1016/j.spinee.2008.01.010.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Lumbar fusion is traditionally used to restore stability after wide surgical decompression for spinal stenosis. The Total Facet Arthroplasty System (TFAS) is a motion-restoring implant suggested as an alternative to rigid fixation after complete facetectomy. To investigate the effect of TFAS on the kinematics of the implanted and adjacent lumbar segments. Biomechanical in vitro study. Nine human lumbar spines (L1 to sacrum) were tested in flexion-extension (+8 to -6Nm), lateral bending (+/-6Nm), and axial rotation (+/-5Nm). Flexion-extension was tested under 400 N follower preload. Specimens were tested intact, after complete L3 laminectomy with L3-L4 facetectomy, after L3-L4 pedicle screw fixation, and after L3-L4 TFAS implantation. Range of motion (ROM) was assessed in all tested directions. Neutral zone and stiffness in flexion and extension were calculated to assess quality of motion. Complete laminectomy-facetectomy increased L3-L4 ROM compared with intact in flexion-extension (8.7+/-2.0 degrees to 12.2+/-3.2 degrees, p<.05) lateral bending (9.0+/-2.5 degrees to 12.6+/-3.2 degrees, p=.09), and axial rotation (3.8+/-2.7 degrees to 7.8+/-4.5 degrees p<.05). Pedicle screw fixation decreased ROM compared with intact, resulting in 1.7+/-0.5 degrees flexion-extension (p<.05), 3.3+/-1.4 degrees lateral bending (p<.05), and 1.8+/-0.6 degrees axial rotation (p=.09). TFAS restored intact ROM (p>.05) resulting in 7.9+/-2.1 degrees flexion-extension, 10.1+/-3.0 degrees lateral bending, and 4.7+/-1.6 degrees axial rotation. Fusion significantly increased the normalized ROM at all remaining lumbar segments, whereas TFAS implantation resulted in near-normal distribution of normalized ROM at the implanted and remaining lumbar segments. Flexion and extension stiffness in the high-flexibility zone decreased after facetectomy (p<.05) and increased after simulated fusion (p<.05). TFAS restored quality of motion parameters (load-displacement curves) to intact (p>.05). The quality of motion parameters for the whole lumbar spine mimicked L3-L4 segmental results. TFAS restored range and quality of motion at the operated segment to intact values and restored near-normal motion at the adjacent segments.
Medical subject headings
- Arthroplasty, Replacement
- Biomechanical Phenomena
- Laminectomy
- Range of Motion, Articular
- Spine
Anatomy
- lumbar spine