Incorporation of C-1 lateral mass screws in occipitocervical and atlantoaxial fusions for children 8 years of age or younger. Technical note.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18459894.
- Also identified by DOI 10.3171/PED-07/08/178.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors describe the novel use of C-1 lateral mass screws in four children 8 years of age or younger, in whom occipitocervical or atlantoaxial fusion was performed for trauma or os odontoideum. The authors retrospectively reviewed the demographics and procedural data of four children, ranging in age from 2 to 8 years, who required and underwent surgical fixation. Although C1-2 screw/rod constructs involving individual C-1 lateral mass screws and C-2 pars interarticularis or pedicle screws have been widely applied in adults, only C1-2 transarticular screw fixation has been reported in children less than 8 years of age. This report demonstrates the successful results of rigid occipitocervical and atlantoaxial fusion in four children in whom C-1 lateral mass screws were placed as part of a screw/rod construct. There was one instance of a vertebral artery injury, and the lessons learned from this complication are discussed.
Medical subject headings
- Atlanto-Axial Joint
- Atlanto-Occipital Joint
- Bone Screws
- Cervical Vertebrae
- Joint Instability
- Spinal Fusion
Anatomy
- cervical spine