Validation of three-dimensional models of in situ scapulae.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 18490182.
- Also identified by DOI 10.1016/j.jse.2008.01.141.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A principal challenge in creating accurate models of in situ scapulae is delineating bone from surrounding soft tissues. Computed tomography scans were obtained of both shoulders of 20 embalmed cadavers. Each shoulder was rescanned after repositioning of the cadavers to test for rescan reliability. After scans were complete, all scapulae were excised and stripped of all soft tissue. Thresholding, region growing, and manual processing were used to create computer-generated 3-dimensional (3D) models. Seven anatomic measurements were performed on each scapula and 3D model. Mean differences between corresponding measurements of specimen and model were small (<3 mm). Intraobserver and interobserver reliability for cadaveric measurements and rescan and interobserver reliability for model measurements were all excellent (R(2) = 0.99). Patient positioning was not a significant source of error in obtaining measurements from 3D models. Results from this work verify that accurate and reproducible 3D models can be created from in situ scapulae by use of effective segmentation.
Medical subject headings
- Imaging, Three-Dimensional
- Models, Biological
- Scapula
- Tomography, X-Ray Computed
Anatomy
- scapula
- shoulder