Intrarater test-retest reliability of hip range of motion and hip muscle strength measurements in persons with hip osteoarthritis.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18503813.
- Also identified by DOI 10.1016/j.apmr.2007.10.028.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To examine the relative and absolute intrarater test-retest reliability of muscle strength and range of motion (ROM) measurements of the hip performed in people with hip osteoarthritis. Repeated measures. Human movement laboratory of a university. Participants (N=22; 10 men, 12 women; age range, 50-84y) with hip osteoarthritis. On 2 separate occasions, at least 1 week apart, isometric torque measurements were obtained from the hip rotators, flexors, abductors, and extensors. Passive ROMs in hip rotation, flexion, abduction, and extension were also determined. Relative reliability was estimated using the intraclass correlation coefficient, model 2,2 (ICC(2,2)). Absolute reliability was estimated using the coefficient of variation (CV) and the standard error (SE) of measurement. For measurements of muscle strength, ICC(2,2) ranged from .84 to .97, and the CV ranged from 8% to 15.7%. Hip extensors and internal and external rotators showed high ICC(2,2) (>.96) and low CV (<9.8%); hip abductors showed the lowest ICC(2,2) (.84) and the highest CV (15.7%). For ROM measurements, ICC(2,2) ranged from .86 to .97 and SE ranged from 3.1 degrees to 4.7 degrees . Hip flexion ROM showed the highest ICC(2,2) (.97) and an SE of 3.5 degrees ; hip extension ROM showed the lowest ICC(2,2) (.86) and the highest SE (4.7 degrees ). Strength and ROM testing of the hip in people with hip osteoarthritis can be performed with good to excellent reliability.
Medical subject headings
- Hip Joint
- Muscle Strength
- Osteoarthritis, Hip
- Range of Motion, Articular
Anatomy
- hip