Biomechanical testing of a novel four-rod technique for lumbo-pelvic reconstruction.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 18520925.
- Also identified by DOI 10.1097/BRS.0b013e31817615c5.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A biomechanical testing protocol was used to study different lumbo-pelvic fixation techniques in a human cadaveric lumbar spine model. To compare the in vitro biomechanics of a novel four-rod lumbo-pelvic reconstruction technique with and with out cross-links, to that of a conventional cross-linked two-rod technique. Numerous lumbo-pelvic reconstruction methods based on the Galveston two-rod technique have been proposed for cases involving total sacrectomy. Recently a technique that proposes novel use of 4 supporting longitudinal rods across the lumbo-pelvic junction has been reported. No comparative in vitro biomechanical testing has been previously done to evaluate these different reconstruction methods. Five spines were evaluated in flexion, extension, left-right lateral bending and left-right axial rotation in a human total sacrectomy model. The model was comprised of cadaveric lumbar spines (L1-L5) with custom fabricated polyethylene blocks used to simulate pelvic fixation. Three conditions were evaluated: Linked Four-Rod, Linked Two-Rod, and Four-Rod (no cross-links). Flexibility and motion data were compared using a one-way repeated measures analysis of variance and SNK tests. The Linked Four-Rod and Four-Rod conditions significantly decreased flexibility and reduced L5-Pelvic motion over the Linked Two-Rod construct in flexion and extension. The Linked Four-Rod condition significantly decreased flexibility in left-right axial rotation compared with the Four-Rod and Linked Two-Rod conditions. No significant differences occurred in relative lateral movement between left and right pelvic polyethylene blocks. The four-rod technique improved fixation stability over the conventional linked two-rod technique in flexion and extension, and when cross-linked, in left-right axial rotation. The four-rod technique also significantly reduced L5-Pelvic junction movement in flexionand extension, which may have implications for bony fusion. The use of cross-links is recommended.
Medical subject headings
- Lumbar Vertebrae
- Orthopedic Fixation Devices
- Pelvic Bones
- Sacrum
- Spinal Fusion
Anatomy
- lumbar spine
- pelvis
- sacrum-coccyx