Modular femoral head and liner exchange for the unstable total hip arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 18534537.
- Also identified by DOI 10.1016/j.arth.2008.03.015.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Outcomes of femoral head and nonconstrained liner exchange in treating hip instability were evaluated. Forty-eight modular component exchanges performed in 45 patients for recurrent hip dislocations were retrospectively reviewed. Mean follow-up was 4.7 years. Overall success rate was 73% (35/48 hips). Thirty-two (67%) of 48 hips experienced no further dislocations. Three patients had 1 dislocation each with no subsequent dislocations. Ten patients (13 hips) had additional surgery to stabilize their hips (27% failure rate). Demographic, clinical, and implant variables were not associated with outcome. Isolated modular component exchange can be successful in treating recurrent hip dislocations; however, a significant failure rate, not easily predicted, exists. This represents the largest series of modular head and nonconstrained liner exchange for hip dislocation (122/125).
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Joint Instability
- Reoperation
Anatomy
- femur
- hip