Incomplete seating of press-fit porous-coated acetabular components: the fate of zone 2 lucencies.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 18555642.
- Also identified by DOI 10.1016/j.arth.2008.04.011.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to asses the fate of incomplete seating of press-fit acetabular components. From 1990 to 2002, 587 hip arthroplasties were performed using a single-design acetabular component inserted with a press-fit technique with no additional fixation. Complete radiographic follow-up at a mean 9.2 years was available for 343 cases. One hundred thirty-three acetabular components had incomplete seating on the initial postoperative radiograph and 210 cases had complete seating. Of 133 components, 125 (94%) had evidence of complete zone 2 filling. Zone 2 focal osteolysis was present in 22 patients. There were no intraoperative fractures. No acetabular components were revised for loosening. Incomplete seating of press-fit acetabular components is safe and effective in achieving initial and long-term fixation. Zone 2 lucencies when present initially are not associated with increased failure risks. Vigorous attempts to completely seat the acetabular component appear to be unwarranted.