Unsuccessful use of a titanium mesh cage in ankle arthrodesis: a report on three cases operated on due to a failed ankle replacement.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18590899.
- Also identified by DOI 10.1053/j.jfas.2008.02.016.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Three patients with a failed total ankle arthroplasty underwent tibiocalcaneal arthrodesis. In an attempt to preserve leg length, a titanium cage filled with autologous bone was placed in the defect. None of the ankles healed primarily. After 9 to 29 months, the cages, which only contained necrotic material, were removed and repeat arthrodesis was performed using a retrograde intramedullary nail. After this procedure, 1 ankle had healed after 14 months whereas 2 did not heal. However, after a third attempt, using external fixation, 1 of the latter 2 healed. The method used in this report cannot be recommended. Although titanium mesh cages filled with autograft have been successfully used to substitute for vertebral defects, the author does not feel that the method can be recommended for ankle arthrodesis.