Prosthetic silicone scaphoid strains: effects of intercarpal fusions.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 1861029.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess stress shielding by partial intercarpal fusion, strains within a silicon scaphoid prosthesis were measured in five fresh upper extremities while the wrist was moved through a functional range of motion before and after capitate-lunate and capitate-hamate-lunate-triquetral intercarpal fusions. Capitate-lunate fusions resulted in an overall 18.4% reduction in compressive strains and a 10.8% reduction in tensile strains. Capitate-hamate-lunate-triquetral fusions reduced compressive strains by 28.5% and tensile strains by 26.3%. Radially deviated positions and positions of extension produced no reduction in strains with the partial fusions. Modest strain shielding can be obtained with partial intercarpal fusions. The effect, however, is position dependent, and whether this degree of strain shielding can reduce the incidence of particulate synovitis remains unknown.
Medical subject headings
- Arthrodesis
- Carpal Bones
- Joint Prosthesis
- Silicone Elastomers
- Wrist Joint
Anatomy
- wrist
- hand