Femoral oxygenation during hip resurfacing through the trochanteric flip approach.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18629596.
- Also identified by DOI 10.1007/s11999-008-0390-5 and PMC identifier 2650040.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Femoral neck fracture is one of the most common complications of hip resurfacing and considered by some to be related to reduced blood flow as a consequence of the surgical approach. We measured oxygen concentration during hip resurfacing through the trochanteric flip approach (n = 15 patients) and compared this approach with previous data for the posterior and anterolateral approaches. With the trochanteric flip the average femoral oxygenation decreased during the procedure to approximately 50% of that at the start, however it recovered to starting level by the end of the procedure. Preservation of oxygenation with the trochanteric flip was similar to that observed with the anterolateral approach, but with less variation during the procedure. Both of these approaches were superior in terms of oxygenation preservation to the posterior approach which resulted in a dramatic reduction in oxygenation.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Femur Head
- Oxygen
Anatomy
- femur
- hip