Bio-medicus ventricular assist device for salvage of cardiac surgical patients.

Killen, D A; Piehler, J M; Borkon, A M; Reed, W A · Ann Thorac Surg · 1991

case_series · Level IV

Where this comes from

Abstract

Over a 5-year period, 41 (1%) of 4,193 patients undergoing cardiac operations underwent intraoperative or early postoperative insertion of a Bio-Medicus ventricular assist device when it became apparent that the patient could not otherwise survive. Fourteen patients were in cardiogenic shock and 7 were in cardiac arrest at the time of initiation of their primary cardiac surgical procedure, and in no instance was the device planned as a bridge to cardiac transplantation. Bleeding, sepsis, and thromboembolism were frequent postoperative complications. Central nervous system deficits were observed in 16 patients during their postoperative course. Eight patients (19.5%) were long-term survivors. Of the preoperative risk factors evaluated only age was significantly associated with survival, with 7 (33%) of the 21 younger (39 to 63 years) patients surviving. Blood product usage and hospital cost were analyzed in an attempt to assess cost/effectiveness of use of this device for attempted salvage of such desperately ill patients.

Medical subject headings