Partial right atrial inflow occlusion for controlled systemic hypotension during thoracic endovascular aortic repair.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18644496.
- Also identified by DOI 10.1016/j.jvs.2008.03.003.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Controlled hypotension is sometimes necessary for accurate endograft deployment and adjunctive ballooning and stenting near the arch and proximal descending thoracic aorta. This article describes a technique in which a compliant occlusion balloon inflated in the right atrium is used to occlude the inflow from the inferior vena cava and reduce the cardiac preload. This reliably and effectively induces systemic hypotension to any desired level and is also able to be rapidly reversed. The technique has been used in 11 cases of thoracic endovascular aortic repairs with complete success and no procedure-related complications.